Single
Phase, Two Stage Filters
Dual Stage Differential mode filter
LJ / SJ SERIES
These filters combine with line to ground interference rejection
filters with additional circuitry to reduce line to line noise and transients.
These filters will protect equipment from malfunctioning due to conducted
interference coming into the equipment from line (susceptibility). They will
also provide needed noise suppression to allow most equipment to meet the
conducted emission limits. They are particularly effective when applied in
equipment using switching power supplies, SCR's for emission control.
|
|
Applications: |
Non-patient contact medical equipments employing SCR to control
the motor speed, Motor drives and control circuits, Switching power supplies,
chromatographs, spectrophotometers, and similar applications.
|
Ordering Information:
|
|
AVAILABLE PART NUMBERS:
ME-1LJ11
ME-3LJ11
ME-6LJ11
ME-1LJ16
ME-3LJ16
ME-6LJ16
|
ME-10SJ20
ME-15SJ20
ME-20SJ20
ME-30SJ20
ME-50SJ20
ME-60SJ20
|
ME-80SJ24
ME-100SJ24
ME-120SJ24
ME-150SJ24
|
|
|
Case Style Dimensions(Click on image to zoom)
|
Case 11 |
Case 16 |
 |
 |
Case 20 |
Case 24 |
 |
 |
|
|
Specifications:
|
Maximum Leakage current(each line to ground):
@250VAC, 50/60 Hz.(Currents <=6A) |
0.5mA |
@250VAC, 50/60 Hz.(Current >6A) |
1.0mA |
Rated voltage:
|
250 VAC |
Operating Frequency:
|
50 / 60 Hz |
Rated current:
|
1,3,6,10,15,20,30,50,
60,80,100,120,& 150A |
Hipot Rating(1 Minute):
Line to Ground |
1500 VAC |
Line to Line |
1450 VDC |
|
Electrical Schematic
|
 |
|
Dimensions are in millimeters, unless otherwise specified. Dimensions are shown for reference purposes only. Specifications subject to change.